| Configuring the SDR33
Follow the steps below to configure your SDR33 data collector for your Leica
TPS300 or TPS1100 Total Station.
Note: Make sure you use the latest SDR firmware ver. 4.26. Also, BIOS ver.
must be higher than 3.01 (between 3.01 and 3.09). To check this from main
menu of the SDR ; Function, then Hardware, then System, then BIOS.
Step Action
1. From the SDR33 main menu, select (F1) FUNC FUNC.
2. Select Instrument Instrument, press OK.
3. Make the following settings:
Type Total Stn
Model TC/TCM Series
Then press OK OK.
4. Select Communications Communications, press OK OK.
5. From the Communications screen, select
(F2) COM COM, press OK OK.
6. Make the following settings:
Port Top
Modem No
Baud Rate 2400
Word Length 7
Parity Even
Stop Bit 1
Output Delay 0
Then press OK OK.
Your SDR33 is now configured to work with your TPS300 or
TPS1100 Total Station!
7. Finally, make sure your Total Station is configured for the SDR33
data collector. See the following sections to configure your
instrument. |