| SDR33
Follow the steps below to configure your SDR33 data collector for your Leica
TPS300 or TPS1100 Total Station.
Note: Make sure you use firmware ver. 4.25. Also, BIOS ver. must be higher than 3.01 (between 3.01 and 3.09). To check this from main menu of the SDR ; Function, then Hardware, then System, then BIOS.
Step Action
1 From the SDR33 main menu, select (F1) FUNC FUNC.
2 Select Instrument Instrument, press OK.
3 Make the following settings:
Type Total Stn
Model TC/TCM Series
Then press OK OK.
4 Select Communications Communications, press OK OK.
5 From the Communications screen, select
(F2) COM COM, press OK OK.
6 Make the following settings:
Port Top - Modem No - Baud Rate 2400 - Word Length 7 - Parity Even - Stop Bit 1 - Output Delay 0; Then press OK.
Your SDR33 is now configured to work with your TPS300 or TPS1100 Total Station!
7 Finally, make sure your Total Station is configured for the SDR33
data collector. See the following sections to configure your
instrument. |